Because of the small capillary tube diameter, the Mats adapts easily to surfaces. The Greata capillary tube mats is good for use in drywall ceilings (floating drywall ceilings,metal tile ceilings, or gypsum board ceilings, ) and also in acoustic plaster ceilings. In drywall ceilings, the mats is placed on gypsum board or floating drywall ceilings or integrated into metal tiles…
Because of the small capillary tube diameter, the Mats adapts easily to surfaces.
The Greata capillary tube mats is good for use in drywall ceilings (floating drywall ceilings,metal tile ceilings, or gypsum board ceilings, ) and also in acoustic plaster ceilings. In drywall ceilings, the mats is placed on gypsum board or floating drywall ceilings or integrated into metal tiles or metal panels or aluminium xps board. With the acoustic plaster ceiling BASWA Cool, the mats is integrated into the acoustic plaster.
The greata mats is also good for use in convective components (ceiling elecment,wall,or floor,). In convectors, such as the GRAVIMAT, the capillary tube mats MATS is integrated into a mounting frame, as is the case with air-water heat exchangers for recovering heat from exhaust air.
TECHNICAL DATA
MATS TYPE
GB 10
SB 10
UB 10
MATERIAL/COLOUR
Polypropylene (PP-R) recyclable/blue
Polypropylene (PP-R) recyclable/blue
Polypropylene (PP-R) recyclable/blue
MAT DISTRIBUTOR PIPE
20 x 2,0 mm, round
20 x 2,0 mm, round
20 x 2,0 mm, round
CAPILLARY TUBE
3,4 x 0,55 mm
3,4 x 0,55 mm
3,4 x 0,55 mm
DISTANCE A
10 mm
10 mm
10 mm
LENGTH L
600 ‐ 7000 mm in 10 mm steps, it can be customized according your size
600 ‐ 7000 mm in 10 mm steps, it can be customized according your size
600 ‐ 7000 mm in 10 mm steps, it can be customized according your size
WIDTH B
100-1000mm in 10 mm steps, it can be customized according your size
100-1000 mm in 20 mm steps, it can be customized according your size
100-1000 mm in 20 mm steps, it can be customized according your size
CONNECTION TYPE
with open mat distributor pipes/
with open mat distributor pipes/
SPEC. WEIGHT
approx. 379 g/m² capillary tube surface
approx. 379 g/m² capillary tube surface
approx. 439 g/m² capillary tube surface
SPEC. VOLUME OF WATER
0,370 l/m² capillary tube surface
0,370 l/m² capillary tube surface
0,430 l/m² capillary tube surface
SPEC. TOTAL WEIGHT
approx. 740 g/m² capillary tube surface
approx. 740 g/m² capillary tube surface
approx. 860 g/m² capillary tube surface
PRESSURE STAGE
PN 10
PN 10
PN 10
FIELD OF APPLICATION
acoustic plaster ceiling drywall ceiling metal ceiling room or wall elements
drywall ceiling or wall floating ceiling metal ceiling
drywall ceiling metal ceiling
Greata HEATING AND COOLING MAT G 10.00
GS 10.00
with open mat distributor pipes for welding
FIELDS OF APPLICATION
acoustic plaster ceiling |BASWA Cool
drywall ceiling | gypsum board panels
metal ceiling | metal tiles, metal panels
room or wall elements | convector GRAVIMAT
aluminium xps board ceiling|
TECHNICAL DATA
MATERIAL/COLOUR
Polypropylene (PP-R) recyclable/blue
MAT DISTRIBUTOR PIPE
20 x 2,0 mm, round
CAPILLARY TUBE
3,4 x 0,55 mm
DISTANCE A
10 mm
LENGTH L
200 ‐ 7000 mm in 10 mm steps,it can be customized
WIDTH B
100-1000mm in 10 mm steps,it can be customized
CONNECTION TYPE
with open mat distributor pipes
SPECATION. WEIGHT
approx. 370 g/m² capillary tube surface
SPECATION VOLUME OF WATER
0,370 l/m² capillary tube surface
SPECATION. TOTAL WEIGHT
approx. 740 g/m² capillary tube surface
PRESSURE STAGE
PN 10
MAX. RECOMMENDED OPERATING PRESSURE
4 bar
MAX. ALLOWABLE HEATING TEMPERATURE
60 °C
Greata HEATING AND COOLING MAT GS 10.00 |
DESIGNATION
GS 10.00
DESCRIPTION
with open mat distributor pipes
PICTOGRAM
FIELDS OF APPLICATION
drywall ceiling or wall | gyspsum board panels
floating ceiling | floating drywall ceiling
metal ceiling | metal tiles, metal panels
TECHNICAL DATA
MATERIAL / COLOUR
Polypropylene (PP-R) recyclable / blue
MAT DISTRIBUTOR PIPE
20 x 2,0 mm, round
CAPILLARY TUBE
3,4 x 0,55 mm
DISTANCE A
10 mm
LENGTH L
200 ‐ 7000 mm in 10 mm steps,it can be customized
WIDTH B
100-1000 mm in 20 mm steps,it can be customized
CONNECTION TYPE
with open mat distributor pipes /
SPECATION. WEIGHT
approx. 380 g/m² capillary tube surface
SPECATION. VOLUME OF WATER
0,380 l/m² capillary tube surface
SPECATION. TOTAL WEIGHT
approx. 780 g/m² capillary tube surface
PRESSURE STAGE
PN 10
MAX. RECOMMENDED OPERATING PRESSURE
4 bar
MAX. ALLOWABLE HEATING TEMPERATURE
60 °C
Greata HEATING AND COOLING capillary tube mats
FIELDS OF APPLICATION
drywall ceiling for gypsum boards
metal ceiling for metal tiles, metal panels
TECHNICAL DATA
MATERIAL/COLOUR
Polypropylene (PP-R) recyclable/blue
MAT DISTRIBUTOR PIPE
20 x 2,0 mm, round
THE SIZE OF CAPILLARY TUBE
3,4 x 0,55 mm
DISTANCE A
10 mm
LENGTH L
200 ‐ 7000 mm in 10 mm steps,it can be customized
WIDTH B
150 -1000mm in 20 mm steps,it can be customized
CONNCETION TYPE
it is can be use for push-lock connections ,also can be normal connect.
There are many adavantage of XPS foam grooves board with Aluminum Foil and with capillary tube mats It is made up of high-strength XPS extruded polystyrene foam board and a layer of the aluminum foils. The products are fabricated in the factory and assembled on site. The surface of our XPS board has reserved grooves…
Radiant heat exchange technology Cooling system radiant heat exchange technology refers to the use of radiant heat exchange methods to transfer heat from the surrounding environment to cool down a system or space. Radiant heat exchange involves the transfer of heat through electromagnetic waves, mainly through infrared radiation. In cooling systems, this technology is utilized…
For the production of Greata capillary tube mats , pipes, supply + return lines we use only high-quality Polypropylen-Random-Copolymerisat (PP-R), DIN EN ISO 19069-1. Specification Capillary Tube Mat Description Sanitary Plumbing Materials ppr pipe and fitting supplier and manufacturer ppr pipe size list : PN 12.5 PN 16 PN 20 PN 25 20*20 20*2.3 20*2.8…
Capillary tube mats for ice storage heat exchange systems are commonly used in buildings for thermal energy storage and air conditioning applications. These mats consist of a network of small-diameter capillary tubes or microtubes that are embedded in a high-conductivity material such as aluminum or copper. The capillary tubes are usually made of copper and…
The water capillary mat system can be used for: The ceiling is the largest free space in the room, thus it is recommended to mount the system on the ceiling, supplementing it with installation on the walls or floor, if it is necessary to provide more heating or cooling capacity. Benefits of the Greata heating system…