Because of the small capillary tube diameter, the Mats adapts easily to surfaces. The Greata capillary tube mats is good for use in drywall ceilings (floating drywall ceilings,metal tile ceilings, or gypsum board ceilings, ) and also in acoustic plaster ceilings. In drywall ceilings, the mats is placed on gypsum board or floating drywall ceilings or integrated into metal tiles…
Because of the small capillary tube diameter, the Mats adapts easily to surfaces.
The Greata capillary tube mats is good for use in drywall ceilings (floating drywall ceilings,metal tile ceilings, or gypsum board ceilings, ) and also in acoustic plaster ceilings. In drywall ceilings, the mats is placed on gypsum board or floating drywall ceilings or integrated into metal tiles or metal panels or aluminium xps board. With the acoustic plaster ceiling BASWA Cool, the mats is integrated into the acoustic plaster.
The greata mats is also good for use in convective components (ceiling elecment,wall,or floor,). In convectors, such as the GRAVIMAT, the capillary tube mats MATS is integrated into a mounting frame, as is the case with air-water heat exchangers for recovering heat from exhaust air.
TECHNICAL DATA
MATS TYPE
GB 10
SB 10
UB 10
MATERIAL/COLOUR
Polypropylene (PP-R) recyclable/blue
Polypropylene (PP-R) recyclable/blue
Polypropylene (PP-R) recyclable/blue
MAT DISTRIBUTOR PIPE
20 x 2,0 mm, round
20 x 2,0 mm, round
20 x 2,0 mm, round
CAPILLARY TUBE
3,4 x 0,55 mm
3,4 x 0,55 mm
3,4 x 0,55 mm
DISTANCE A
10 mm
10 mm
10 mm
LENGTH L
600 ‐ 7000 mm in 10 mm steps, it can be customized according your size
600 ‐ 7000 mm in 10 mm steps, it can be customized according your size
600 ‐ 7000 mm in 10 mm steps, it can be customized according your size
WIDTH B
100-1000mm in 10 mm steps, it can be customized according your size
100-1000 mm in 20 mm steps, it can be customized according your size
100-1000 mm in 20 mm steps, it can be customized according your size
CONNECTION TYPE
with open mat distributor pipes/
with open mat distributor pipes/
SPEC. WEIGHT
approx. 379 g/m² capillary tube surface
approx. 379 g/m² capillary tube surface
approx. 439 g/m² capillary tube surface
SPEC. VOLUME OF WATER
0,370 l/m² capillary tube surface
0,370 l/m² capillary tube surface
0,430 l/m² capillary tube surface
SPEC. TOTAL WEIGHT
approx. 740 g/m² capillary tube surface
approx. 740 g/m² capillary tube surface
approx. 860 g/m² capillary tube surface
PRESSURE STAGE
PN 10
PN 10
PN 10
FIELD OF APPLICATION
acoustic plaster ceiling drywall ceiling metal ceiling room or wall elements
drywall ceiling or wall floating ceiling metal ceiling
drywall ceiling metal ceiling
Greata HEATING AND COOLING MAT G 10.00
GS 10.00
with open mat distributor pipes for welding
FIELDS OF APPLICATION
acoustic plaster ceiling |BASWA Cool
drywall ceiling | gypsum board panels
metal ceiling | metal tiles, metal panels
room or wall elements | convector GRAVIMAT
aluminium xps board ceiling|
TECHNICAL DATA
MATERIAL/COLOUR
Polypropylene (PP-R) recyclable/blue
MAT DISTRIBUTOR PIPE
20 x 2,0 mm, round
CAPILLARY TUBE
3,4 x 0,55 mm
DISTANCE A
10 mm
LENGTH L
200 ‐ 7000 mm in 10 mm steps,it can be customized
WIDTH B
100-1000mm in 10 mm steps,it can be customized
CONNECTION TYPE
with open mat distributor pipes
SPECATION. WEIGHT
approx. 370 g/m² capillary tube surface
SPECATION VOLUME OF WATER
0,370 l/m² capillary tube surface
SPECATION. TOTAL WEIGHT
approx. 740 g/m² capillary tube surface
PRESSURE STAGE
PN 10
MAX. RECOMMENDED OPERATING PRESSURE
4 bar
MAX. ALLOWABLE HEATING TEMPERATURE
60 °C
Greata HEATING AND COOLING MAT GS 10.00 |
DESIGNATION
GS 10.00
DESCRIPTION
with open mat distributor pipes
PICTOGRAM
FIELDS OF APPLICATION
drywall ceiling or wall | gyspsum board panels
floating ceiling | floating drywall ceiling
metal ceiling | metal tiles, metal panels
TECHNICAL DATA
MATERIAL / COLOUR
Polypropylene (PP-R) recyclable / blue
MAT DISTRIBUTOR PIPE
20 x 2,0 mm, round
CAPILLARY TUBE
3,4 x 0,55 mm
DISTANCE A
10 mm
LENGTH L
200 ‐ 7000 mm in 10 mm steps,it can be customized
WIDTH B
100-1000 mm in 20 mm steps,it can be customized
CONNECTION TYPE
with open mat distributor pipes /
SPECATION. WEIGHT
approx. 380 g/m² capillary tube surface
SPECATION. VOLUME OF WATER
0,380 l/m² capillary tube surface
SPECATION. TOTAL WEIGHT
approx. 780 g/m² capillary tube surface
PRESSURE STAGE
PN 10
MAX. RECOMMENDED OPERATING PRESSURE
4 bar
MAX. ALLOWABLE HEATING TEMPERATURE
60 °C
Greata HEATING AND COOLING capillary tube mats
FIELDS OF APPLICATION
drywall ceiling for gypsum boards
metal ceiling for metal tiles, metal panels
TECHNICAL DATA
MATERIAL/COLOUR
Polypropylene (PP-R) recyclable/blue
MAT DISTRIBUTOR PIPE
20 x 2,0 mm, round
THE SIZE OF CAPILLARY TUBE
3,4 x 0,55 mm
DISTANCE A
10 mm
LENGTH L
200 ‐ 7000 mm in 10 mm steps,it can be customized
WIDTH B
150 -1000mm in 20 mm steps,it can be customized
CONNCETION TYPE
it is can be use for push-lock connections ,also can be normal connect.
Greata Capillary Tube Mats Use the Natural Capillary Effect for Heat Transfer or cooling transfer Particularly energy efficient Even heat distribution Suitable for heating and cooling Diverse uses Wide assortment Good value for save cost Capillary tube mats are typically used for heating purposes, such as in underfloor systems. The mats consist of a network…
Welcome to greata General FAQs for capillary tube mats CAPILLARY TUBE MATS FROM greata BASIC SHAPES OF GREATA CAPILLARY TUBE MATS ADVANTAGES COMPARED TO THE SINGLE-PIPE SYSTEM Edit Content All Greata capillary tube mats are made in China from high quality polypropylene according to the ISO 9001 and CE standard. Constantly further developed production machines…
The aluminum foil insulation XPS foam board with grooved for capillary tube mats xps extruded polystyrene underfloor heating insulation board, xps mould foam board insulation backed with aluminum foil Extrusion board is a kind of material which is continuously extruded and foamed by a special process. The surface of the Extrusion board is even and…
Greata is a high-tech enterprise specializing in the development and production of capillary tube mats in China, with a tradition of more than sixteen years. We use only high-quality PPR raw materials and German automatic capillary tube mat production line. The unique welding process and mature production experience ensure that each piece of the capillary…
To produce greata capillary tube mats, follow these steps: Remember to always follow safety guidelines and use appropriate materials and tools when handling capillary tubes and adhesives. Additionally, consider any specific requirements or instructions provided by the manufacturer of the capillary tubes or mat material. we guarantee a 15-year warranty on greata capillary tube mats.
Capillary tube mats for ice storage heat exchange systems are commonly used in buildings for thermal energy storage and air conditioning applications. These mats consist of a network of small-diameter capillary tubes or microtubes that are embedded in a high-conductivity material such as aluminum or copper. The capillary tubes are usually made of copper and…