Because of the small capillary tube diameter, the Mats adapts easily to surfaces. The Greata capillary tube mats is good for use in drywall ceilings (floating drywall ceilings,metal tile ceilings, or gypsum board ceilings, ) and also in acoustic plaster ceilings. In drywall ceilings, the mats is placed on gypsum board or floating drywall ceilings or integrated into metal tiles…
Because of the small capillary tube diameter, the Mats adapts easily to surfaces.
The Greata capillary tube mats is good for use in drywall ceilings (floating drywall ceilings,metal tile ceilings, or gypsum board ceilings, ) and also in acoustic plaster ceilings. In drywall ceilings, the mats is placed on gypsum board or floating drywall ceilings or integrated into metal tiles or metal panels or aluminium xps board. With the acoustic plaster ceiling BASWA Cool, the mats is integrated into the acoustic plaster.
The greata mats is also good for use in convective components (ceiling elecment,wall,or floor,). In convectors, such as the GRAVIMAT, the capillary tube mats MATS is integrated into a mounting frame, as is the case with air-water heat exchangers for recovering heat from exhaust air.
TECHNICAL DATA
MATS TYPE
GB 10
SB 10
UB 10
MATERIAL/COLOUR
Polypropylene (PP-R) recyclable/blue
Polypropylene (PP-R) recyclable/blue
Polypropylene (PP-R) recyclable/blue
MAT DISTRIBUTOR PIPE
20 x 2,0 mm, round
20 x 2,0 mm, round
20 x 2,0 mm, round
CAPILLARY TUBE
3,4 x 0,55 mm
3,4 x 0,55 mm
3,4 x 0,55 mm
DISTANCE A
10 mm
10 mm
10 mm
LENGTH L
600 ‐ 7000 mm in 10 mm steps, it can be customized according your size
600 ‐ 7000 mm in 10 mm steps, it can be customized according your size
600 ‐ 7000 mm in 10 mm steps, it can be customized according your size
WIDTH B
100-1000mm in 10 mm steps, it can be customized according your size
100-1000 mm in 20 mm steps, it can be customized according your size
100-1000 mm in 20 mm steps, it can be customized according your size
CONNECTION TYPE
with open mat distributor pipes/
with open mat distributor pipes/
SPEC. WEIGHT
approx. 379 g/m² capillary tube surface
approx. 379 g/m² capillary tube surface
approx. 439 g/m² capillary tube surface
SPEC. VOLUME OF WATER
0,370 l/m² capillary tube surface
0,370 l/m² capillary tube surface
0,430 l/m² capillary tube surface
SPEC. TOTAL WEIGHT
approx. 740 g/m² capillary tube surface
approx. 740 g/m² capillary tube surface
approx. 860 g/m² capillary tube surface
PRESSURE STAGE
PN 10
PN 10
PN 10
FIELD OF APPLICATION
acoustic plaster ceiling drywall ceiling metal ceiling room or wall elements
drywall ceiling or wall floating ceiling metal ceiling
drywall ceiling metal ceiling
Greata HEATING AND COOLING MAT G 10.00
GS 10.00
with open mat distributor pipes for welding
FIELDS OF APPLICATION
acoustic plaster ceiling |BASWA Cool
drywall ceiling | gypsum board panels
metal ceiling | metal tiles, metal panels
room or wall elements | convector GRAVIMAT
aluminium xps board ceiling|
TECHNICAL DATA
MATERIAL/COLOUR
Polypropylene (PP-R) recyclable/blue
MAT DISTRIBUTOR PIPE
20 x 2,0 mm, round
CAPILLARY TUBE
3,4 x 0,55 mm
DISTANCE A
10 mm
LENGTH L
200 ‐ 7000 mm in 10 mm steps,it can be customized
WIDTH B
100-1000mm in 10 mm steps,it can be customized
CONNECTION TYPE
with open mat distributor pipes
SPECATION. WEIGHT
approx. 370 g/m² capillary tube surface
SPECATION VOLUME OF WATER
0,370 l/m² capillary tube surface
SPECATION. TOTAL WEIGHT
approx. 740 g/m² capillary tube surface
PRESSURE STAGE
PN 10
MAX. RECOMMENDED OPERATING PRESSURE
4 bar
MAX. ALLOWABLE HEATING TEMPERATURE
60 °C
Greata HEATING AND COOLING MAT GS 10.00 |
DESIGNATION
GS 10.00
DESCRIPTION
with open mat distributor pipes
PICTOGRAM
FIELDS OF APPLICATION
drywall ceiling or wall | gyspsum board panels
floating ceiling | floating drywall ceiling
metal ceiling | metal tiles, metal panels
TECHNICAL DATA
MATERIAL / COLOUR
Polypropylene (PP-R) recyclable / blue
MAT DISTRIBUTOR PIPE
20 x 2,0 mm, round
CAPILLARY TUBE
3,4 x 0,55 mm
DISTANCE A
10 mm
LENGTH L
200 ‐ 7000 mm in 10 mm steps,it can be customized
WIDTH B
100-1000 mm in 20 mm steps,it can be customized
CONNECTION TYPE
with open mat distributor pipes /
SPECATION. WEIGHT
approx. 380 g/m² capillary tube surface
SPECATION. VOLUME OF WATER
0,380 l/m² capillary tube surface
SPECATION. TOTAL WEIGHT
approx. 780 g/m² capillary tube surface
PRESSURE STAGE
PN 10
MAX. RECOMMENDED OPERATING PRESSURE
4 bar
MAX. ALLOWABLE HEATING TEMPERATURE
60 °C
Greata HEATING AND COOLING capillary tube mats
FIELDS OF APPLICATION
drywall ceiling for gypsum boards
metal ceiling for metal tiles, metal panels
TECHNICAL DATA
MATERIAL/COLOUR
Polypropylene (PP-R) recyclable/blue
MAT DISTRIBUTOR PIPE
20 x 2,0 mm, round
THE SIZE OF CAPILLARY TUBE
3,4 x 0,55 mm
DISTANCE A
10 mm
LENGTH L
200 ‐ 7000 mm in 10 mm steps,it can be customized
WIDTH B
150 -1000mm in 20 mm steps,it can be customized
CONNCETION TYPE
it is can be use for push-lock connections ,also can be normal connect.
System Description The concept of the Greata Hydro capillary tube system was developed on the basis of the human blood circulatory system and the structure of plant leaves. The Greata Hydro capillary tube system consists of water capillary mats, a flow distribution system, connection pipes and fittings, measuring and control devices, a heat exchanger (if necessary),…
Welcome to greata General FAQs for capillary tube mats CAPILLARY TUBE MATS FROM greata BASIC SHAPES OF GREATA CAPILLARY TUBE MATS ADVANTAGES COMPARED TO THE SINGLE-PIPE SYSTEM Edit Content All Greata capillary tube mats are made in China from high quality polypropylene according to the ISO 9001 and CE standard. Constantly further developed production machines…
pipe cooling mat -ice rinks mat Industry-specific attributes Processing Service Moulding, Cutting Other attributes Place of Origin:Jiangsu, China Brand Name: Greata Model Number :ICE-100 Product name :ice rink mat Operation Pressure:0.5-2.5Bar Operation Temperature :-45C to + 120C Size:117*9*6mm ,123*12*8mm,131*12*8mm Application:Outdoor Recreation(Removable ice skating mats) Packing:Carton Box Color:Black or white Suitable places:Outdoor Location Feature:Flexible Material:ICE-EPDM,NBR+PVC Packaging…
Radiant heat exchange technology Cooling system radiant heat exchange technology refers to the use of radiant heat exchange methods to transfer heat from the surrounding environment to cool down a system or space. Radiant heat exchange involves the transfer of heat through electromagnetic waves, mainly through infrared radiation. In cooling systems, this technology is utilized…
The optimized capillary tube mat with a more robust capillary tube for heating and cooling for all applications where the capillary tube mat is exposed to increased mechanical and/or thermal stress. so The capillary tube mats has been developed for “rough” construction site operation. The capillary tube mats is suitable for use in plaster, screed, concrete…