  • Technical data for Greata CAPILLARY TUBE MAT

    capillary tue mat certificate

    Technical data for CAPILLARY TUBE MAT

    MAT DESIGNATION GT 10 GT 20 GT 20
    MATERIAL/COLOUR Polypropylene (PP-R) recyclable/blue Polypropylene (PP-R) recyclable/blue Polypropylene (PP-R) recyclable/blue
    MAT DISTRIBURTOR PIPE 20 x 2,0 mm, round 20 x 2,0 mm, round 20 x 2,0 mm, round
    CAPILLARY TUBE MAT 4,3 x 0,8 mm 4,3 x 0,8 mm 4,3 x 0,8 mm
    DISTANCE A 10 mm 20 mm 20 mm
    LENGTH L 600 ‐ 6000 mm in 10 mm steps 600 ‐ 6000 mm in 10 mm steps 600 ‐ 6000 mm in 10 mm steps
    WIDTH B as from 150 mm in 20 mm steps as from 150 mm in 20 mm steps as from 150 mm in 20 mm steps
    CONNECTION TYPE with open mat distributor pipes/with 2 push-lock connections 10 mm or 15 mm with open mat distributor pipes/with 2 push-lock connections 10 mm or 15 mm with open mat distributor pipes/with 2 push-lock connections 10 mm or 15 mm
    SPEC. WEIGHT approx. 870 g/m² capillary tube Mat surface approx. 430 g/m² capillary tube mat surface approx. 430 g/m² capillary tube mat surface
    SPEC. VOLUME OF WATER 0,570 l/m² capillary tube mat surface 0,320 l/m² capillary tube mat surface 0,320 l/m² capillary tube mat surface
    SPEC. TOTAL WEIGHT approx. 1440 g/m² capillary tube mat surface approx. 750 g/m² capillary tube mat surface approx. 750 g/m² capillary tube mat surface
    PRESSURE STAGE PN 10 PN 10 PN 10
    MAX. RECOMMENDED OPERATING PRESSURE 4 bar 4 bar 4 bar
    MAX. ALLOWED HEATING TEMPERATURE 60 °C 60 °C 60 °C
    FIELD OF APPLICATION
    • drywall ceiling or wall
    • metal ceiling
    • concrete ceiling or wall
    • plaster ceiling or wall
    • floor
    • facade
    • concrete ceiling or wall
    • plaster ceiling or wall
    • floor
    • soil
    • facade

     

  • Thermal sensor, Thermocouple type K

    Thermal sensor, Thermocouple type K for capillary tube mats system TECHNICAL DATA: Type: Thermocouple, type K Temperature sensing range: up to 900°C Temperature accuracy: +/- 2°C Wire material: Fiberglass Measuring end termination: “Cable eye” for M4 screw Wire length: 40cm Product Advantages 1:Accurate measurement (imported chip) 2:fast response,  anti-interference, 3: waterproof and corrosion resistant (304 probe…

  • TWO WAY FOR DRYWALL CEILING WITH CAPILLARY TUBE MATS

    Inquiry
    - Select Department -sells departmentengineer deparmentGeneral managerhuman department
    window.fluent_form_ff_form_instance_4_1 = {"id":"4","settings":{"layout":{"labelPlacement":"top","helpMessagePlacement":"with_label","errorMessagePlacement":"inline"},"restrictions":{"denyEmptySubmission":{"enabled":false}}},"form_instance":"ff_form_instance_4_1","form_id_selector":"fluentform_4","rules":{"names[first_name]":{"required":{"value":true,"message":"First Name field is required","global":false,"global_message":"This field is required"}},"names[middle_name]":{"required":{"value":false,"message":"This field is required","global":false,"global_message":"This field is required"}},"names[last_name]":{"required":{"value":false,"message":"This field is required","global":false,"global_message":"This field is required"}},"phone_1":{"required":{"value":true,"message":"This field is required"},"valid_phone_number":{"value":true,"message":"Phone number is not valid"}},"email":{"required":{"value":true,"message":"Email field is required","global":false,"global_message":"This field is required"},"email":{"value":true,"message":"This field must contain a valid email","global":false,"global_message":"This field must contain a valid email"}},"department":{"required":{"value":true,"message":"Department field is required","global":false,"global_message":"This field is required"}},"subject":{"required":{"value":true,"message":"Subject field is required","global":false,"global_message":"This field is required"}},"description":{"required":{"value":false,"message":"This field is required","global":false,"global_message":"This field is required"}},"g-recaptcha-response":[]}};
  • XPS board with 0.2 mm plain aluminum embedded in shaped grooves with capillary tube mat

    Inquiry
    - Select Department -sells departmentengineer deparmentGeneral managerhuman department
    window.fluent_form_ff_form_instance_4_2 = {"id":"4","settings":{"layout":{"labelPlacement":"top","helpMessagePlacement":"with_label","errorMessagePlacement":"inline"},"restrictions":{"denyEmptySubmission":{"enabled":false}}},"form_instance":"ff_form_instance_4_2","form_id_selector":"fluentform_4","rules":{"names[first_name]":{"required":{"value":true,"message":"First Name field is required","global":false,"global_message":"This field is required"}},"names[middle_name]":{"required":{"value":false,"message":"This field is required","global":false,"global_message":"This field is required"}},"names[last_name]":{"required":{"value":false,"message":"This field is required","global":false,"global_message":"This field is required"}},"phone_1":{"required":{"value":true,"message":"This field is required"},"valid_phone_number":{"value":true,"message":"Phone number is not valid"}},"email":{"required":{"value":true,"message":"Email field is required","global":false,"global_message":"This field is required"},"email":{"value":true,"message":"This field must contain a valid email","global":false,"global_message":"This field must contain a valid email"}},"department":{"required":{"value":true,"message":"Department field is required","global":false,"global_message":"This field is required"}},"subject":{"required":{"value":true,"message":"Subject field is required","global":false,"global_message":"This field is required"}},"description":{"required":{"value":false,"message":"This field is required","global":false,"global_message":"This field is required"}},"g-recaptcha-response":[]}};